CBBYJ - REPLENISHER RP58SY, 12939-0027
- MSDS: CBBYJ
- Manufacturer: CALCOMP
- Product Name: REPLENISHER RP58SY, 12939-0027
- National Stock Number: 6750-00N036180
Product Identification
Product ID:REPLENISHER RP58SY, 12939-0027
MSDS Date:05/21/1992
FSC:6750
NIIN:00N036180
MSDS Number: CBBYJ
Responsible Party
ANAHEIM, CA 92801
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 714-821-2730
Cage: IO122
Contractor
Telephone: 714-821-2290
Cage: 14668
Ingredients
MINERAL SPIRITS; (ALIPHATIC HYDROCARBON (ISOPAR G))
CAS: 64475-85-0
RTECS: PY8240000
Fraction By Weight: >80%
OSHA PEL N/K
ACGIH TLV: N/K
POLY-2-ETHYLHEXYL METHACRYLATE COPOLYMER
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: N/K
PIGMENT; (YELLOW) PIGMENT
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: N/K
NORMAL CNDTNS OF USE. UNDER SOME CNDNTNS OF
RTECS: 9999999ZZ
SHOULD ASSURE THAT VENT IS SUFFICIENT TO PVNT
RTECS: 9999999ZZ
ENGINEER AND/OR INUDSTRIAL HYGIENIST IF A CONCERN
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SKIN:CAN CAUSE DRYING/IRRIT.
EYES:CONT MAY CAUSE IRRIT. INHAL:VAPS MAY CAUSE HDCHS & DIZZ.
INGEST:PROD HAS LOW ORDER OF ACUTE ORAL & DERM TOX, BUT IF ASPIR
INTO LUNGS DURING INGEST/VOMIT, MAY CA USE MILD TO SEV PULM INJURY
& POSSIBLY DEATH. SIGNS & SYMPS OF OVEREXP:HIGH VAP CONC (>1000
PPM) ARE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:IRRIT TO EYES & RESP TRACT, MAY CAUSE
HDCHS & DIZZ, ARE ANESTH, & MAY HAVE OTHER CNS EFTS. DEATH IS POSS
IF EXPOS TO VERY HIGH CONC FOR PRLNGD PERIODS. PERSONS SENSITIVE TO
HYDROCARB EXPOS MA Y EXPERIENCE DISCOMFORT WHEN EXPOS TO CONC BELOW
ESTABLISHED SAFE EXPOS LIM (SEE INGRED SECTION FOR EXPOS LIM INFO).
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS.
First Aid
First Aid:EYE:FLUSH W/CLEAR WATER FOR @ LEAST 15 MINS/UNTIL IRRIT
SUBSIDES. IF IRRIT PERSISTS, CONT PHYS. SKIN:REMOVE CONTAMD CLTHG.
WASH THORO W/SOAP & WATER. DO NOT REUSE CONTAMD CLTHG UNTIL SOLVS
HAVE BEEN R EMOVED. INHAL:REMOVE VICTIM TO FRESH AIR. CALL PHYS
IMMED. IF BRTHG IS IRREGULAR/STOPPED, START RESUSCITATION IF
TRAINED. ADMIN OXYG IF AVAIL. INGEST:DILUTE CONTENTS OF STOM
W/SEVERAL GLASSES (SUPDAT)
Fire Fighting
Flash Point Method:TCC
Flash Point:>102F,>39C
Lower Limits:0.8%
Upper Limits:7.0%
Extinguishing Media:FOAM, DRY CHEMICAL, OR CARBON DIOXIDE (CO*2). USE
WATER SPRAY (FOG) TO COOL FIRE.
Fire Fighting Procedures:NORMAL PROCEDURE FOR COMBUSTIBLE LIQUIDS. USE
NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:KEEP PROD AWAY FROM SOURCES OF IGNIT SUCH
AS HEAT, SPKS, PILOT LIGHTS, STATIC ELECTRICITY, ELEC APPLIANCES &
OPEN FLAMES. AVOID EXTING W/WATER-IT TENDS (SUPDAT)
Accidental Release
Spill Release Procedures:NONE SPECIFIED BY MANUFACTURER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
USE. MINIMIZE BREATHING VAPOR OR MIST. USE WITH ADEQUATE
VENTILATION.
Other Precautions:AVOID PROLONGED OR REPEATED SKIN CONTACT.
Exposure Controls
Respiratory Protection:NOT NEEDED WHEN USED AS INTENDED WITH MFR
PRODUCTS. IN CONCENTRATIONS EXCEEDING RECOMMENDED SAFE EXPOSURE
LIMIT, SUCH AS DURING A MAJOR SPILL, USE NIOSH/MSHA APPRVD CHEMICAL
CARTRIDGE RESPIRATOR EFFEC TIVE FOR ORGANIC VAPORS.
Ventilation:NO SPEC VENT IS NEEDED WHEN USED AS INTENDED W/MFR PRODS.
NORM OFFICE VENT CONFORMING TO AMERICAN SOCIETY OF (SUPDAT)
Protective Gloves:NITRILE/NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:CHEMICAL RESISTANT APRON. ANSI APPRVD EYE
WASH & DELUGE SHOWER .
Work Hygienic Practices:DO NOT SMOKE WHEN USING PROD. ALWAYS USE GOOD
PERSONAL HYGIENE PRACTICES, SUCH AS WASHING YOUR HANDS AFTER DONE.
Supplemental Safety and Health
SPEC GRAV:0.75-0.82 (H*2O=1). VP:<10 @ 25 1/2C. PH:ESSENTIALLY NEUTRAL.
% VOLAT:80-98 @ 1 ATM & 25 1/2C(77 1/2F). EXPLO HAZ:TO SPREAD
HYDROCARB SOLV FIRES. FIRST AID PROC:OF WATER. DO NOT INDUCE VOMIT
. CALL PHYS IMMED. VENT:HEATING, AIR CONDITIONING, & REFRIGERATING
ENGINEERS(ASHRAE) 1980 STDS IS ADEQ UNDER (ING 4)
Chemical Properties
Boiling Pt:B.P. Text:>320F,>160C
Vapor Pres:SUPDAT
Vapor Density:5.0
Spec Gravity:SUPDAT
pH:SUPDAT
Evaporation Rate & Reference:0.3 (N-BUTYL ACETATE =1)
Solubility in Water:NEGLIGIBLE; 0.1%
Appearance and Odor:YELLOW LIQUID. FAINT PETROLEUM HYDROCARBON ODOR.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS LIKE LIQUID CHLORINE, CONCENTRATED OXYGEN, AND SODIUM
HYPOCHLORITE OR CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:SOURCES OF IGNITION.
Hazardous Decomposition Products:SMOKE, CARBON MONOXIDE, ALDEHYDES, &
OTHER DECOMP PRODUCTS WHICH MAY OCCUR IN THE EVENT OF INCOMPLETE
COMBUSTION.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.